Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Am J Infect Control ; 2022 Jun 13.
Artículo en Inglés | MEDLINE | ID: covidwho-2232579

RESUMEN

We describe an outbreak of SARS-CoV-2 on a transition unit composed of elderly patients awaiting placement. Environmental and patient sample analyses using digital droplet PCR (ddPCR) suggested possible fomite transmission and a high viral burden source from a few individual patients. This outbreak illustrates challenges inherent to this specific patient population.

2.
Arch Pathol Lab Med ; 146(7): 805-813, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1912033

RESUMEN

CONTEXT.­: Reverse transcription-polymerase chain reaction (RT-PCR) is the standard method of diagnosing COVID-19. An inconclusive test result occurs when 1 RT-PCR target is positive for SARS-CoV-2 and 1 RT-PCR target is negative for SARS-CoV-2 within the same sample. An inconclusive result generally requires retesting. One reason why a sample may yield an inconclusive result is that one target is at a higher concentration than another target. OBJECTIVE.­: To understand the role of subgenomic RNA transcripts in discordant results from RT-PCR tests for COVID-19. DESIGN.­: A panel of 6 droplet digital PCR assays was designed to quantify the ORF1, E-gene, and N-gene of SARS-CoV-2. This panel was used to quantify viral cultures of SARS-CoV-2 that were harvested during the eclipse phase and at peak infectivity. Eleven clinical nasopharyngeal swabs were also tested with this panel. RESULTS.­: In culture, infected cells showed higher N-gene/ORF1 copy ratios than culture supernatants. The same trends in the relative abundance of copies across different targets observed in infected cells were observed in clinical samples, although trends were more pronounced in infected cells. CONCLUSIONS.­: This study showed that a greater copy number of N-gene relative to E-gene and ORF1 transcripts could potentially explain inconclusive results for some RT-PCR tests on low viral load samples. The use of N-gene RT-PCR target(s) as opposed to ORF1 targets for routine testing is supported by these data.


Asunto(s)
COVID-19 , COVID-19/diagnóstico , Humanos , ARN , ARN Viral/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Transcripción Reversa , SARS-CoV-2/genética
3.
J Clin Microbiol ; 60(1): e0165921, 2022 01 19.
Artículo en Inglés | MEDLINE | ID: covidwho-1854231

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged into a world of maturing pathogen genomics, with more than 2 million genomes sequenced at the time of writing. The rise of more transmissible variants of concern that impact vaccine and therapeutic effectiveness has led to widespread interest in SARS-CoV-2 evolution. Clinicians are also eager to take advantage of the information provided by SARS-CoV-2 genotyping beyond surveillance purposes. Here, we review the potential role of SARS-CoV-2 genotyping in clinical care. The review covers clinical use cases for SARS-CoV-2 genotyping, methods of SARS-CoV-2 genotyping, assay validation and regulatory requirements, and clinical reporting for laboratories, as well as emerging issues in clinical SARS-CoV-2 sequencing. While clinical uses of SARS-CoV-2 genotyping are currently limited, rapid technological change along with a growing ability to interpret variants in real time foretells a growing role for SARS-CoV-2 genotyping in clinical care as continuing data emerge on vaccine and therapeutic efficacy.


Asunto(s)
COVID-19 , Enfermedades Transmisibles , Consenso , Genotipo , Humanos , SARS-CoV-2 , Estados Unidos
4.
Pediatr Infect Dis J ; 41(7): 566-569, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1774432

RESUMEN

We compared the perfomance of SARS-CoV-2 reverse transcriptase real-time polymerase chain reaction (RT-PCR) to droplet digital PCR (ddPCR). 95% and 40% of positive and negative RT-PCR specimens, respectively, were positive on ddPCR yielding sensitivities of 84% (95% CI: 74, 91) and 97% (95% CI: 89, 99), for RT-PCR and ddPCR, respectively. We found that SARS-CoV-2 RT-PCR testing in children has a concerning false-negative rate at lower nucleocapsid gene copy numbers.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/epidemiología , Niño , Servicio de Urgencia en Hospital , Humanos , Estudios Prospectivos , ARN Viral/análisis , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/genética , Sensibilidad y Especificidad , Carga Viral
5.
Diagn Microbiol Infect Dis ; 102(3): 115606, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: covidwho-1604132

RESUMEN

The SARS-CoV-2 coronavirus pandemic has been an unprecedented challenge to global pandemic response and preparedness. With the continuous appearance of new SARS-CoV-2 variants, it is imperative to implement tools for genomic surveillance and diagnosis in order to decrease viral transmission and prevalence. The ADSSpike workflow was developed with the goal of identifying signature SNPs from the S gene associated with SARS-CoV-2 variants through amplicon deep sequencing. Seventy-two samples were sequenced, and 30 mutations were identified. Among those, signature SNPs were linked to 2 Zeta-VOI (P.2) samples and one to the Alpha-VOC (B.1.17). An average depth of 700 reads was found to properlycorrectly identify all SNPs and deletions pertinent to SARS-CoV-2 mutants. ADSSpike is the first workflow to provide a practical, cost-effective, and scalable solution to diagnose SARS-CoV-2 VOC/VOI in the clinical laboratory, adding a valuable tool to public health measures to fight the COVID-19 pandemic for approximately $41.85 USD/reaction.


Asunto(s)
COVID-19 , SARS-CoV-2 , Genómica , Humanos , Mutación , Pandemias
6.
Arch Pathol Lab Med ; 146(1): 26-33, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1595050

RESUMEN

CONTEXT.­: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a highly infectious agent, with the propensity to cause severe illness. While vaccine uptake has been increasing in recent months, many regions remain at risk of significant coronavirus disease 19 (COVID-19)-related health care burden. Health systems will continue to benefit from the availability of a variety of clinical and laboratory models when other triaging models are equivocal. OBJECTIVE.­: To validate previously reported clinical laboratory abnormalities seen in COVID-19 patients and identify what laboratory parameters might be outcome predictive. DESIGN.­: We undertook an observational study of hospital-admitted COVID-19 patients (n = 113), looking at a broad selection of clinical, laboratory, peripheral blood smear, and outcome data during discrete discovery and validation periods from March 2020 to November 2020. RESULTS.­: We confirmed the findings of previous studies noting derangement of a variety of laboratory parameters in COVID-19 patients, including peripheral blood morphologic changes. We also devised a simple-to-use decision tree by which patients could be risk stratified on the basis of red blood cell count, creatinine, urea, and atypical plasmacytoid lymphocyte ("covidocyte") count. This outcome classifier performed comparably to the World Health Organization clinical classifier and the neutrophil-lymphocyte ratio. CONCLUSIONS.­: Our data add to the increasing number of studies cataloguing laboratory changes in COVID-19 and support the clinical utility of incorporating blood morphologic assessment in the workup of hospitalized COVID-19 patients.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Laboratorios , Laboratorios Clínicos , Medición de Riesgo
7.
J Clin Virol ; 145: 105025, 2021 12.
Artículo en Inglés | MEDLINE | ID: covidwho-1514205

RESUMEN

An unbiased metagenomics approach to virus identification can be essential in the initial phase of a pandemic. Better molecular surveillance strategies are needed for the detection of SARS-CoV-2 variants of concern and potential co-pathogens triggering respiratory symptoms. Here, a metagenomics workflow was developed to identify the metagenome diversity by SARS-CoV-2 diagnosis (npositive = 65; nnegative = 60), symptomatology status (nsymptomatic = 71; nasymptomatic = 54) and anatomical swabbing site (nnasopharyngeal = 96; nthroat = 29) in 125 individuals. Furthermore, the workflow was able to identify putative respiratory co-pathogens, and the SARS-CoV-2 lineage across 29 samples. The diversity analysis showed a significant shift in the DNA-metagenome by symptomatology status and anatomical swabbing site. Additionally, metagenomic diversity differed between SARS-CoV-2 infected and uninfected asymptomatic individuals. While 31 co-pathogens were identified in SARS-CoV-2 infected patients, no significant increase in pathogen or associated reads were noted when compared to SARS-CoV-2 negative patients. The Alpha SARS-CoV-2 VOC and 2 variants of interest (Zeta) were successfully identified for the first time using a clinical metagenomics approach. The metagenomics pipeline showed a sensitivity of 86% and a specificity of 72% for the detection of SARS-CoV-2. Clinical metagenomics can be employed to identify SARS-CoV-2 variants and respiratory co-pathogens potentially contributing to COVID-19 symptoms. The overall diversity analysis suggests a complex set of microorganisms with different genomic abundance profiles in SARS-CoV-2 infected patients compared to healthy controls. More studies are needed to correlate severity of COVID-19 disease in relation to potential disbyosis in the upper respiratory tract. A metagenomics approach is particularly useful when novel pandemic pathogens emerge.


Asunto(s)
COVID-19 , SARS-CoV-2 , Prueba de COVID-19 , Humanos , Metagenómica , Flujo de Trabajo
8.
Clin Infect Dis ; 74(8): 1496-1502, 2022 04 28.
Artículo en Inglés | MEDLINE | ID: covidwho-1501061

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged into a world of maturing pathogen genomics, with >2 million genomes sequenced at this writing. The rise of more transmissible variants of concern that affect vaccine and therapeutic effectiveness has led to widespread interest in SARS-CoV-2 evolution. Clinicians are also eager to take advantage of the information provided by SARS-CoV-2 genotyping beyond surveillance purposes. Here, we review the potential role of SARS-CoV-2 genotyping in clinical care. The review covers clinical use cases for SARS-CoV-2 genotyping, methods of SARS-CoV-2 genotyping, assay validation and regulatory requirements, clinical reporting for laboratories, and emerging issues in clinical SARS-CoV-2 sequencing. While clinical uses of SARS-CoV-2 genotyping are currently limited, rapid technological change along with a growing ability to interpret variants in real time foretell a growing role for SARS-CoV-2 genotyping in clinical care as continuing data emerge on vaccine and therapeutic efficacy.


Asunto(s)
COVID-19 , Enfermedades Transmisibles , COVID-19/prevención & control , Consenso , Genotipo , Humanos , SARS-CoV-2/genética
9.
Sci Rep ; 11(1): 13378, 2021 06 28.
Artículo en Inglés | MEDLINE | ID: covidwho-1286471

RESUMEN

The highly infectious nature of SARS-CoV-2 necessitates the use of widespread testing to control the spread of the virus. Presently, the standard molecular testing method (reverse transcriptase-polymerase chain reaction, RT-PCR) is restricted to the laboratory, time-consuming, and costly. This increases the turnaround time for getting test results. This study sought to develop a rapid, near-patient saliva-based test for COVID-19 (Saliva-Dry LAMP) with similar accuracy to that of standard RT-PCR tests. A lyophilized dual-target reverse transcription-loop-mediated isothermal amplification (RT-LAMP) test with fluorometric detection by the naked eye was developed. The assay relies on dry reagents that are room temperature stable. A device containing a centrifuge, heat block, and blue LED light system was manufactured to reduce the cost of performing the assay. This test has a limit of detection of 1 copy/µL and achieved a positive percent agreement of 100% [95% CI 88.43% to 100.0%] and a negative percent agreement of 96.7% [95% CI 82.78-99.92%] relative to a reference standard test. Saliva-Dry LAMP can be completed in 105 min. Precision, cross-reactivity, and interfering substances analysis met international regulatory standards. The combination of ease of sample collection, dry reagents, visual detection, low capital equipment cost, and excellent analytical sensitivity make Saliva-Dry LAMP particularly useful for resource-limited settings.


Asunto(s)
COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/análisis , Saliva/virología , COVID-19/virología , Fluorometría , Humanos , Límite de Detección , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Diagnóstico Molecular/normas , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Técnicas de Amplificación de Ácido Nucleico/normas , ARN Viral/normas , Estándares de Referencia , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Temperatura
10.
Water Res ; 201: 117369, 2021 Aug 01.
Artículo en Inglés | MEDLINE | ID: covidwho-1272771

RESUMEN

SARS-CoV-2 has been detected in wastewater and its abundance correlated with community COVID-19 cases, hospitalizations and deaths. We sought to use wastewater-based detection of SARS-CoV-2 to assess the epidemiology of SARS-CoV-2 in hospitals. Between August and December 2020, twice-weekly wastewater samples from three tertiary-care hospitals (totaling > 2100 dedicated inpatient beds) were collected. Hospital-1 and Hospital-2 could be captured with a single sampling point whereas Hospital-3 required three separate monitoring sites. Wastewater samples were concentrated and cleaned using the 4S-silica column method and assessed for SARS-CoV-2 gene-targets (N1, N2 and E) and controls using RT-qPCR. Wastewater SARS-CoV-2 as measured by quantification cycle (Cq), genome copies and genomes normalized to the fecal biomarker PMMoV were compared to the total daily number of patients hospitalized with active COVID-19, confirmed cases of hospital-acquired infection, and the occurrence of unit-specific outbreaks. Of 165 wastewater samples collected, 159 (96%) were assayable. The N1-gene from SARS-CoV-2 was detected in 64.1% of samples, N2 in 49.7% and E in 10%. N1 and N2 in wastewater increased over time both in terms of the amount of detectable virus and the proportion of samples that were positive, consistent with increasing hospitalizations at those sites with single monitoring points (Pearson's r = 0.679, P < 0.0001, Pearson's r = 0.799, P < 0.0001, respectively). Despite increasing hospitalizations through the study period, nosocomial-acquired cases of COVID-19 (Pearson's r = 0.389, P < 0.001) and unit-specific outbreaks were discernable with significant increases in detectable SARS-CoV-2 N1-RNA (median 112 copies/ml) versus outbreak-free periods (0 copies/ml; P < 0.0001). Wastewater-based monitoring of SARS-CoV-2 represents a promising tool for SARS-CoV-2 passive surveillance and case identification, containment, and mitigation in acute- care medical facilities.


Asunto(s)
COVID-19 , SARS-CoV-2 , Brotes de Enfermedades , Humanos , Centros de Atención Terciaria , Carga Viral , Aguas Residuales
11.
Open Forum Infect Dis ; 8(4): ofab095, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: covidwho-1195735

RESUMEN

Testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in symptomatic and asymptomatic patients is an important component of the multifaceted approach of managing the coronavirus disease 2019 pandemic. Determining how to best define testing strategies for different populations and incorporating these into broader infection prevention programs can be complex. Many circumstances are not addressed by federal, local, or professional guidelines. This commentary describes various scenarios in which testing of symptomatic or asymptomatic individuals for SARS-CoV-2 virus (antigen or ribonucleic acid) can be of potential benefit. Consideration to pretest probability, risks of testing (impact of false-positive or false-negative results), testing strategy, as well as action based on test results are explored. Testing, regardless of setting, must be incorporated into overarching infection control plans, which include use of personal protective equipment (eg, masks), physically distancing, and isolation when exposure is suspected.

12.
Am J Transplant ; 21(7): 2590-2595, 2021 07.
Artículo en Inglés | MEDLINE | ID: covidwho-1099683

RESUMEN

Solid organ transplant recipients are vulnerable to severe infection during induction therapy. We report a case of a 67-year-old male who died unexpectedly 10 days after receiving a kidney transplant on February 10, 2020. There was no clear cause of death, but COVID-19 was considered retrospectively, as the death occurred shortly after the first confirmed case of COVID-19 in Canada. We confirmed the presence of SARS-CoV-2 components in the renal allograft and native lung tissue using immunohistochemistry for SARS-CoV-2 spike protein and RNA scope in situ hybridization for SARS-CoV-2 RNA. Results were reaffirmed with the Food and Drug Administration Emergency Use Authorization approved Bio-Rad SARS-CoV-2 digital droplet PCR for the kidney specimen. Our case highlights the importance of patient autopsies in an unfolding global pandemic and demonstrates the utility of molecular assays to diagnose SARS-CoV-2 post-mortem. SARS-CoV-2 infection during induction therapy may portend a fatal clinical outcome. We also suggest COVID-19 may be transmittable via renal transplant.


Asunto(s)
COVID-19 , Trasplante de Riñón , Anciano , Autopsia , Canadá , Humanos , Trasplante de Riñón/efectos adversos , Masculino , ARN Viral/genética , Estudios Retrospectivos , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Receptores de Trasplantes
13.
J Virol Methods ; 286: 113972, 2020 12.
Artículo en Inglés | MEDLINE | ID: covidwho-759120

RESUMEN

A novel reverse-transcriptase loop mediated amplification (RT-LAMP) method targeting genes encoding the Spike (S) protein and RNA-dependent RNA polymerase (RdRP) of SARS-CoV-2 has been developed. The LAMP assay achieves a comparable limit of detection (25-50 copies per reaction) to commonly used RT-PCR protocols using clinical samples quantified by digital droplet PCR. Precision, cross-reactivity, inclusivity, and limit of detection studies were performed according to regulatory standards. Clinical validation of dual-target RT-LAMP (S and RdRP gene) achieved a PPA of 98.48 % (95 % CI 91.84%-99.96%) and NPA 100.00 % (95 % CI 93.84%-100.00%) based on the E gene and N2 gene reference RT-PCR methods. The method has implications for development of point of care technology using isothermal amplification.


Asunto(s)
Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/virología , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Neumonía Viral/diagnóstico , Neumonía Viral/virología , ARN Viral/aislamiento & purificación , COVID-19 , Prueba de COVID-19 , Simulación por Computador , Proteínas de la Envoltura de Coronavirus , Humanos , Pandemias , Sistemas de Atención de Punto , ARN Viral/genética , ADN Polimerasa Dirigida por ARN , SARS-CoV-2 , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/genética , Proteínas del Envoltorio Viral/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA